27 years of three-dimensional ultrasound imaging

Authors

  • Sonila Pashaj
  • Eberhard Merz

DOI:

https://doi.org/10.55312/op.vi1.4389

Abstract

Diagnostic ultrasound, a non-invasive diagnostic tool in prenatal diagnosis, has been shaped by enormous technological progress over the last three decades. The aim of this clinical review is to demonstrate the development of three dimensional (3D) ultrasound and their importance in improvement of prenatal diagnoses.

Keywords:

3D ultrasound, history, prenatal diagnosis.

Downloads

Download data is not yet available.

Author Biographies

Sonila Pashaj

Spitali Universitar Obsterik-Gjinekologji `Koço Gliozheni

Eberhard Merz

Centre for Ultrasound and Prenatal Medicine, Frankfurt/Main, Germany

References

  1. Szilard J. An improved three-dimensional display system. Ultrasonics. 1974; 76: 273-6.

  2. Sohn C, Grotepass J, Ameling W et al. Prerequisites for the clinical application of 3-dimensional ultrasonic imaging. Radialoge 1989; 29: 303-307.

  3. Kirbach D, Whittingham TA, 3D ultrasound– the Kretztchnik VolusonR approach. Eur J Ultrasound 1994; 1: 85-89

  4. Merz E. Current 3-D/4-D ultrasound technology in prenatal diagnosis. Eur Clin Obstet Gynaecol. 2005; 1; 184-193.

  5. Merz E, Benoit B, Blass GH, Baba K, Kratochwil A, Nelson T, Pretorius D, Jurkovic S, Chang MF, Lee A. Standardization of three-dimensional

  6. images in obstetrics and gynecology: consensus statement. Ultrasound Obstet Gynecol. 2007; 29: 697-703.

  7. Merz E. 3-D ultrasound in prenatal diagnosis. In: Merz E (ed). Ultrasound in Obstetrics and Gynecology, Vol 1: Obstetrics. Stuttgart – New York: Thieme; 2005: 516-528.

  8. Merz E, Weber G, Bahlmann F et al. Application of transvaginal and abdominal three-dimensional ultrasound for the detection or exclusion of malformations of the fetal face. Ultrasound Obstet Gynecal 1997; 9: 237-243.

  9. Monteagudo A, Timor-Tritsch IE, Mayberry P. Three-dimensional transvaginal neurosonography of the fetal brain: ‘‘navigating’’

  10. in the volume scan. Ultrasound Obstet Gynecol. 2000; 16: 307–313.

  11. Merz E. 25 Years of 3D ultrasound in prenatal diagnosis (1989-2014). Ultraschall Med. 2015. 36; 3-8. Doi:10.1055/s-0034-1398866.

  12. Devore GR, Falkensammer P, Sklansky MS et al. Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart. Ultrasound Obstet Gynecal 2003: 22: 380-387.

  13. Rotten D, Levaillant JM. Two- and threedimensional sonographic assessment of the fetal face. 2. Analysis of cleft lip, alveolus and palate.

  14. Ultrasound Obstet Gynecal 2004: 24: 402-411.

  15. Chaoui R, Heling KS. New developments in fetal heart scanning: three and four-dimensional fetal echocardiography. Semin Fetal Neonatal Med 2005; 10: 567-577.

  16. Benacerraf BR, Benson CB, Abuhamad AZ et al. Three and 4-dimensional ultrasound in obstetrics and gynecology; proceedings of the

  17. American Institute of Ultrasound in Medicine Consensus Conference. J Ultrasound Med 2005; 24: 1587-1597.

  18. Merz E, Welter C. 2D and 3D ultrasound evaluation of normal and abnormal fetal anatomy in the second and third trimester in a level III center. Ultraschall in Med 2005: 1587-1597.

  19. Benoit B, Chaoui R. Three.dimensional ultrasound with maximal mode rendering: a novel technique for the diagnosis of bilateral or

  20. unilateral absence or hypoplasia of nasal ones in second trimesters screening for Down syndrome. Ultrasound Obstet Gynecaol 2005;26:9-16.

  21. Kurjak A, Miskovic B, Stanojevic M et al. New scoring system for the fetal neurobehaviour assessed by three and four- dimensional sonography. J Perinata Med 2008; 36: 73-81.

  22. Merz E, Abramowicz JS. 3D/4D ultrasound in prenatal diagnoses: is it time for routine use? Clinical Obstetrics and gynecology: 2012; 33:

  23. -182.

  24. Pashaj S, Merz E, Wellek S. Biometric measurements of the fetal corpus callosum by three-dimensional ultrasound. Ultrasound Obstet Gynecol 2013: 42: 691-698.

  25. Merz E, Pashaj S. Current role of 3-D/4D sonography in obstetrics and gynecology. Donald School. J Ultrasound Obstetrics Gynecology 2013; 7 : 400-408.

  26. Pashaj S, Merz E. Prenatal demonstration of the normal variants of the pericallosal artery by 3D ultrasound. Ultraschall in Med. 2014. 35. 129-136.

  27. Bonilla-Musoles F, Raga F, Osborne NG et al. Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an

  28. emphasis in HD live technique. Ultrasound Q 2013; 29:189-201.

  29. Rolo LC, Santana EF, da Silva PH et al. Fetal cardiac interventricular septum: volume assessment by 3D/4D ultrasound using spatiotemporal image correlation (STIC) and virtual organ computer aided analysis (VOCAL). J Matern fetal Neonatal Med 2014; 10: 1-6.

  30. Enzensberger C, Degenhardt J, Tenzer A et al. First experience with three-dimensional speckle tracking (3D motion tracking) in fetal

  31. echocardiography. Ultraschall in Med 2014; 35: 566-572.

  32. Tonni G, Grisolia G, Sepulveda W. Second trimester fetal neurosonography: reconstructing cerebral midline anatomy and anomalies using

  33. a novel three-dimensional ultrasound technique. Prenat Diagn 2014; 34: 75-83.

  34. Leibovitz Z, Haratz KK, Malinger G et al. Fetal posterior fossa dimensions: nomrla and nomalous development assessed in mid.sagittal cranial plane by three-dimensional multiplanar sonography. Ultrasound Obstet Gynecol 2014; 43: 147-153

  35. Chaoui R, Heling KS, Karl K. Ultrasound o the fetal veins. Part 1: the intrahepatic venous system. Ultraschall in Med 2014; 35: 208-228.

  36. Chaoui R, Heling KS, Karl K. Ultrasound of the fetal veins. Part 2: the intrahepatic venous system. Ultraschall in Med 2014; 35: 302-321.

  37. Hartge DR, Schröer A, Weichert J. Novel Insights into Early Embrionic Demise via 3D Surface rendering Imaging in 107 cases. Ultraschall in

  38. Med 2014; 540-546.

  39. Pooh RK, Kurjak A. Novel application of three-dimensional HD live imaging in prenatal diagnosis from the fi rst trimester. J PerinaT Med

  40. , DOI: 10.1515/jpm-2014-0157.

  41. Merz E. 3D/4D ultrasound in obstetrics – Baby TV without diagnostics? Ultraschal in Med 2008; 29: 156-158.

  42. Merz E. Transvaginal 3D/4D ultrasound and its application in gynecology. In: Merz E (ed). Ultrasound in Obstetrics and Gynecology. Vol

  43. Gynecology. Stuttgart – New York: Thieme : 2007.

  44. Merz E. 3-D ultrasound in Obstetrics and Gynecology. Lippincott Williams and Wilkins. Philadelphia, 1998.

  45. Merz E. 3-D Ultrasound in prenatal diagnosis. In: Merz E, (ed). Ultrasound in Obstetrics, Stuttgart – New York: Thieme 2005.

  46. Merz E. Tomographic ultrasound imaging. Ultraschall Med. 2006; 27: 307-308.

  47. Timor-Tritsch IE, Monteagudo A. Three and four-dimensional ultrasound in obstetrics and gynecology. Curr Opin Obstet Gynecol. 2007;

  48. : 157-175.

  49. Viñals F, Munoz M, Naveas R, Schalper J, Giuliano S. The fetal cerebellar vermis: anatomy and biometry assessment using 4D volume

  50. contrast imaging in the C-plane (VCI-C). Ultrasound Obstet Gynecol. 2005; 26: 622–627.

  51. Merz E. Current 3-D/4-D ultrasound technology in prenatal diagnosis. Eur Clin Obstet Gynaecol. 2005; 1; 184-93.

  52. Lee W, Goncalves L, Espinoza J, Romero R. Inversion mode. A new volume analysis tool for 3-dimensional ultrasonography. J Ultrasound

  53. Med. 2005; 24: 201-7.

  54. Benoit B. The volume of three-dimensional ultrasonography in the screening of the fetal skeleton. Child Nerv Syst. 2003; 10: 403-409.

  55. Chaoui R, Hoff mann J, Heling KS. Threedimansional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC). Ultrasound Obstet Gynecol. 2004;23:535-545.

  56. Monteagudo A, Timor-Tritsch IE. Normal sonographic development of the central nervous system from the second trimester onwards using 2-D, 3-D and transvaginal sonography. Prenat Diag. 2009; 29: 326-339.

  57. Correa FF, Lara C, Bellver J, Remohi J, Pellicer A, Serra V. Examination of the fetal brain by transabdominal threedimensional ultrasound:

  58. potential for routine neurosonographic studies. Ultrasound Obstet Gynecol. 2006; 27: 503–508.

  59. Miguelote FR, Vides B, Santos FR, Palha AJ, Matias A, Sousa N. The role of tridimensional imaging reconstruction to measure the corpus

  60. callosum: comparison with direct mid-sagittal views. Prenat Diagn. 2011: DOI: 10. 1002/ pd.2794.

  61. Rizzo G, Pietrolucci ME, Capponi A, Arduini D. Assessment of corpus callosum Biometric measurement at 18 to 32 weeks´gestation by

  62. -dimensional sonography. J Ultrasound Med. 2011;30: 47-53.

  63. Pilu G, Segata M, Ghi T, Carletti A, Perolo A, Santini D, Bonasoni P, Tani G, Rizzo N. Diagnosis of midline anomalies of the fetal brain with the three- dimensional median view. Ultrasound Obstet Gynecol. 2006.27: 522–529.

Downloads

Published

2024-05-13

How to Cite

Pashaj, S., & Merz, E. (2024). 27 years of three-dimensional ultrasound imaging. Optime, (1), 37–46. https://doi.org/10.55312/op.vi1.4389

Issue

Section

Medical Sciences

Categories